Tornado Enclosure User Manual page 28
Control Interface
Heater is ON, to maintain lower temperature
level or to prevent condensation
Lamp is ON, or Temperature is HIGH and
Fan is cooling enclosure. Short burst when lamp
off indicates fan moving air to stabilize
temp/humidity
Current sensing shows lamp is ON
Lamp hour counter is running
Current sensing shows lamp is OFF
Lamp hour counter is not running
Lamp relay is closed (normal)
Luminaire power receptacle is energized
Lamp relay is open due to over-temperature
event. Luminaire power receptacle is isolated.
Temperature is below lower temp setting
Temperature is in normal range
Humidity is above target limit
Temperature is above top setting
Temperature is above Trip level
Luminaire power is isolated
DEC3.3 is in BASIC Mode – DMX not used. OR
DEC3.3 is in Monitor or Control Mode and no
valid DMX or RDM packet has been detected.
Good DMX or RDM data packet received.
Control Mode: DMX Fail. A previously good DMX
signal has failed.
Monitor Mode: No RDM information being
received (this is normal)